Pipe Fitting & Fabrication
Our team members include experienced welders and pipefitters who specialize in all facets of pump work, working with various types of pipes and fittings, intake screens for lakes and streams, etc., racks for outdoor electrical panels, including:
- Pipe welding—carbon steel, 304 and 316 stainless steel, aluminum
- Ductile iron pipe and fittings: flanged and mechanical joint
- HDPE pipe—fusion welding
- Grooved end pipe
- Copper pipe
- Replacement pump station manifolds in carbon and stainless steel
- Transitions between different types or sizes of pipe.
- Pipe threading: black, galvanized and stainless steel, aluminum pipe
- Stainless steel box screens for pump intake screens in lakes
- Combination HDPE and stainless steel intakes in shallow streams and rivers
- Aluminum sleds for check valves, submersible pumps, other submerged equipment
- Electrical panel racks-aluminum and stainless steel.
- Elevated platforms in flood prone areas
- Bridge crossings
We can provide you with shop-built assemblies fabricated to precise dimensions or dispatch a field crew for demanding work on site, custom Z-pipes, or underground piping. If you need help connecting your pump system to a water source or to a distribution system, give ProPump & Controls a call. We can get the job done!
ProPump & Controls crews are OSHA trained and safety certified by ISNetworld to ensure a safe work environment at your facility.
Welding & Fabrication
- Certified Pipe Welders
- On Site or in Shop fabrication
- Carbon Steel, Stainless Steel, Aluminum
HDPE Piping
- Full array fusion services
- Butt Fusion
- Electrofusion
- Extrusion Welding
- Factory Certified Technicians on McElroy Fusion Equipment
Thermal Imaging
- Electrical Fault Analysis
- Switchgear Inspection
- Motor Bearing Failures
- Pump Fan and Compressor Wear
- Liquid Level in Tanks
- Motor Amperage Imbalance
- Loose Electrical Connections
- Faulty Circuit Breakers
- Defective Insulator Bushings
- Transformer and Capacitor Failures
- Overhead Distribution Faults
- Inadequate Insulation
- Moisture Contamination
Laser Alignment
- Decreased Wear on Bearing Seals and Couplings
- Reduced Machinery Vibration
- Reduced Unscheduled Down Time
- Error Free and Accurate Measurements to 0.00001”
- Reduced Energy Consumption
Ultrasonic Thickness Testing
- Completely Nondestructive
- Equipment Can Quickly, Effectively, and Inexpensively Generate an Image Of The Materials Inner Structure